IDS805 USER MANUAL NO. 700-266-01A ISSUED NOV 2003 VER 1.00 25
IDS805 USER MANUAL
15.1.1Viewing Trouble Conditions
[7]
(Hold down the key until the keypad buzzer sounds)
If the POWER LED is flashing (or if so programmed, the keypad is
beeping) hold down the [7] key for two seconds. The ARMED, AWAY
and READY indicators will start flashing to show that the keypad is in
the TROUBLE viewing mode. Refer to the table below to find the
significance of each illuminated zone LED. The system will
automatically exit the TROUBLE mode after ten seconds. To clear the
trouble condition press [#] within 5 seconds of viewing. To simply
cancel the beeping without viewing the trouble conditions, press [#].
rotacidnI noitidnoCelbuorT
2ynapmocgnirotinomotetacinummocoteruliaF
3eruliafrewopsniaM
4yrettabwoL
5tneserptonsirotucneebsahenilenohpeleTehT
6nwolbsahesufehtrotucneebsaheriwnerisehT
7repmatadecneirepxesahdapyeK
8noitidnocmralanaraelcotderetneebtsumedocsrellatsnI
N.B.
If the zone 8 LED is illuminated contact your alarm installer
immediately. Until an installer code has been entered, the system will
NOT arm.
15.2 Problems When Arming the System
Is the code correct?
If you enter the wrong user code the keypad will beep three times and
the system will not arm.
Is the READY Indicator illuminated?
If this indicator is not illuminated, one or more zones are violated. A
violation is shown by a flashing zone indicator. Ensure that all
monitored doors and windows are closed. Bypassing a violated zone