Safety Information and Precautions MD380 User Manual
- 12 -
8VH6WDJH
Safety
Grade
Precautions
During
operation
DANGER
Signal detection during running must be performed only by
TXDOL¿HGSHUVRQQHO)DLOXUHWRFRPSO\PD\UHVXOWLQSHUVRQDO
injury or equipment damage.
Do not touch the fan or the discharging resistor to check the
WHPSHUDWXUH2WKHUZLVH\RXPD\JHWEXUQW
WARNING
Prevent dropping objects into the AC drive during drive running.
Failure to comply may result in damage to the AC drive.
Do not start or stop the AC drive by turning on or off the
contactor. Failure to comply may result in equipment damage.
During
maintenance
DANGER
Repair or maintenance of the AC drive may be performed only
E\TXDOL¿HGSHUVRQQHO)DLOXUHWRFRPSO\PD\UHVXOWLQSHUVRQDO
injury or equipment damage.
Do not repair or maintain the AC drive at power-on. Failure to
comply will result in electric shock.
Repair or maintain the AC drive at least ten minutes after the
AC drive is powered off. This allows for the residual voltage in
the capacitor to discharge to a safe value. Failure to comply will
result in personal injury.
Ensure that the AC drive is disconnected from all power supplies
before starting the repair or maintenance work.
All the pluggable components must be plugged or removed only
after power-off.
Set and check the parameters again after the AC drive is
replaced.
WARNING
The rotating motor generally feeds back power to the AC drive.
As a result, the AC drive is still energized even if the motor
stops, and the power supply is cut off. Thus ensure that the AC
drive is completely disconnected from the motor before starting
the repair or maintenance work.
1.2 General Precautions
1) Requirement on residual current device (RCD)
7KH$&GULYHJHQHUDWHVKLJKOHDNDJHFXUUHQWGXULQJUXQQLQJZKLFKÀRZVWKURXJKWKH
protective earthing (PE) conductor. Thus install a type-B residual current device (RCD)
DWSULPDU\VLGHRIWKHSRZHUVXSSO\:KHQVHOHFWLQJWKH5&'\RXVKRXOGFRQVLGHUWKH
transient and steady-state leakage current to ground that may be generated at startup
and during running of the AC drive. You can select a specialized RCD with the function
of suppressing high harmonics or a general-purpose RCD with relatively large residual
current.