Goodrive20 inverters Function Parameters
38
Function
code
Name Detailed instruction of parameters
Default
value
Modify
When the set frequency is above the lower limit one again
and it lasts for the time set by P01.20, the inverter will run
automatically.
Setting range: 0.0~3600.0s (valid when P01.19=2)
P01.21
Restart after
power off
This function can enable the inverter start or not after the
power off and then power on.
0: Disabled
1: Enabled, if the starting need is met, the inverter will run
automatically after waiting for the time defined by P01.22.
0
P01.22
The waiting
time of restart
after power off
The function determines the waiting time before the
automatic running of the inverter when powering off and
then powering on.
Setting range: 0.0~3600.0s (valid when P01.21=1)
1.0s
P01.23
Start delay time
The function determines the brake release after the running
command is given, and the inverter is in a stand-by state
and wait for the delay time set by P01.23
Setting range: 0.0~60.0s
0.0s
P01.24
Delay of the
stopping speed
Setting range: 0.0~100.0s 0.0s
P01.25
0Hz output
Select the 0Hz output of the inverter.
0: Output without voltage
1: Output with voltage
2: Output at the DC braking current
0
P02 Group Motor 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT GD20-0R7G-4 and is the answer not in the manual?

INVT GD20-0R7G-4 Specifications

General IconGeneral
BrandINVT
ModelGD20-0R7G-4
CategoryDC Drives
LanguageEnglish

Related product manuals