Goodrive20 inverters Function Parameters
77
Function
code
Name Detailed instruction of parameters
Default
value
Modify
After the users select the corresponding ACC/DEC time, the
combining 16 binary bit will change into decimal bit, and
then set the corresponding function codes.
Setting range: -0x0000~0xFFFF
P10.36
PLC restart
mode
0: Restart from the first stage; stop during running (cause by
the stop command, fault or power loss), run from the first
stage after restart.
1: Continue to run from the stop frequency; stop during
running(cause by stop command and fault), the inverter will
record the running time automatically, enter into the stage
after restart and keep the remaining running at the setting
frequency.
0
◎
Multi-step time
unit selection
0: Seconds; the running time of all stages is counted by
second
1: Minutes; the running time of all stages is counted by
minute
0
◎
P11 Group Protective parameters