74
LBK System Series| Instruction manual v1.2 SET 2021 |SAF-UM-LBKBus-en-v1.2|© 2020-2021 Inxpect SpA
7. Maintenance and troubleshooting
LED Status
Inxpect Safety
application messages
Problem Remedy
S6 Steady red FEE ERROR, FLASH
ERROR or RAM ERROR
Configuration saving
error, configuration not
performed or memory
error
Reconfigure or configure the
system, see "Manage the
configuration" on page71.
If the error persists, please contact
assistance service.
S1–S6
together
Steady red FIELDBUS ERROR Communication error
on the Fieldbus
At least one input or output is
configured as Fieldbus controlled.
Check that the cable is correctly
connected, communication with the
host is correctly established and the
exchanged data are maintained
passivated by the host itself.
S1–S5
together
Steady red DYNAMIC
CONFIGURATION ERROR
Error in the selection of
the dynamic
configuration: invalid
ID
Check the preset configurations
within the Inxpect Safety
application.
S1–S4
together
Steady red SENSOR
CONFIGURATIONERROR
Error during the
configuration of the
sensors
Check the sensors connected and
try again to perform the
configuration of the system via the
Inxpect Safety application.
At least
one LED
Flashing
red
"Sensor LED" on the next
page
Sensor corresponding
to the flashing LED in
error ** ("Sensor LED"
on the next page)
Check the problem through the LED
on the sensor.
At least
one LED
Flashing
green
"Sensor LED" on the next
page
Sensor corresponding
to the flashing LED in
error ** ("Sensor LED"
on the next page)
If the issue persists longer than one
minute, please contact assistance
service.
All the
LEDs
Steady
orange
- The system is starting
up.
Wait for a few seconds.
All the
LEDs
Flashing
green one
after the
other in
sequence
The control unit is in
boot state.
Please contact assistance service.
Note: fault signal on the control unit (steady LED) takes priority over a faulty sensor signal. For the status of the
single sensor, check the sensor LED.
Note*: S1 is the first from the top.
Note**: S1 corresponds to the sensor with ID 1, S2 corresponds to the sensor with ID 2 and so on.
7.1.2 Sensor LED
Status
Inxpect Safety
application messages
Problem Remedy
2 flashes * CANERROR ID not assigned Assign a Node ID to the sensor, see
"Connect the control unit to the sensors"
on page67.
3 flashes * CANERROR Error in communication
with the control unit
Check connections of all sensors in the
chain starting from the last sensor in error.
4 flashes * SENSOR
TEMPERATUREERROR or
SENSOR POWERERROR
Wrong power supply
voltage or temperature
value
l Check the sensor connection and that
the length of the cables respects
maximum limits.
l Check that the ambient temperature
where the system is functioning
complies with the operating
temperatures indicated in the technical
data in this manual

Table of Contents

Other manuals for Inxpect ISC-B01

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inxpect ISC-B01 and is the answer not in the manual?

Inxpect ISC-B01 Specifications

General IconGeneral
BrandInxpect
ModelISC-B01
CategorySafety Equipment
LanguageEnglish

Related product manuals