Functions and Features
Status register, the OP status bit is set to 1.
Enable OPP
1. Press [Shift]+[Recall] (Protect) to enter Protect menu interface.
2. Use left and right keys or rotate the knob to select OPP and press [Enter]
key to confirm.
3. Use left and right keys or rotate the knob to select On and press [Enter] key
to confirm.
4. Rotate the knob to adjust the over-power limit Level and press [Enter] key
to confirm.
5. Rotate the knob to adjust the delay time Delay and press [Enter] key to
confirm.
6. Press [Esc] to exit the protection menu setting.
Clear Over-Power Protection
To clear the over-power and return to normal operation, firstly remove the condi-
tions that caused the protection fault. Press [Esc] key (or send the command
PROTection:CLEar) to clear the protection status. The “Over Power Protect”
displayed in front panel is cleared and the instrument exits OPP status.
4.3.5 Set Under-Voltage Protection
Under-voltage protection function allows the user to enable the protection and
set a under-voltage limit (Level), delay time (Delay) and warm-up time (
Warm Up).
An under-voltage protection will occur if:
Enable UVP;
The output time exceeds the warm-up time;
Warm-up time Warm Up You can specify the warm-up time for UVP pro-
tection to make the instrument not judge the under-voltage protection fault
within the specified warm-up time.
The output voltage value is less than the set voltage protection point Level
and the period is greater than the set protection delay time Delay.
Delay time Delay You can specify an UVP delay to prevent momentary
output settings, DUT and status changes from tripping the under-voltage
protection. In most cases these momentary conditions would not be consid-
ered an under-voltage protection fault, and having an UVP condition disable
the output when they occur would be a nuisance. Specifying an UVP delay
lets the UVP circuit ignore these momentary changes during the specified
Copyright © Itech Electronic Co., Ltd.
53

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3140 Series and is the answer not in the manual?

ITech IT-M3140 Series Specifications

General IconGeneral
BrandITech
ModelIT-M3140 Series
CategoryPower Supply
LanguageEnglish

Related product manuals