Functions and Features
Enable FOLDBACK function
1. Press [Shift]+[Recall] (Protect) to enter Protect menu interface.
2. Use left and right keys or rotate the knob to select FOLDBACK and press
[Enter] key to confirm.
3. Select CC or CV and press [Enter] key to confirm.
• Selecting CC means that the instrument triggers protection when the
operating mode of the instrument switches to CC mode.
• Selecting CV means that the instrument triggers protection when the
operating mode of the instrument is switched to CV mode.
• Select OFF to turn off the foldback function.
4. Rotate the knob to adjust the Delay and press [Enter] key to confirm.
5. Press [Esc] to exit the protection menu setting.
Delay FOLDBACK
You can specify a time for the FOLDBACK delay, which can make the
instrument ignore the instantaneous change of the operating mode in the
specified delay interval. In most cases, this instantaneous situation is not
considered as a switching state, and there is no need to trigger the foldback
function and disable Output. Once the FOLDBACK delay time is exceeded, the
output is turned off.
4.4 List Function
The user can use list function to create a test program made of multiple steps.
Up to 10 programs (List1 to List10) can be created in the list mode for this series
power supplies. Each list program can be made of up to 100 steps. The user
need to set voltage or current, slope and dwell time for each step. The user also
can set repeat times, end state and so on for each list program. The descrip-
tions of list function menu are listed in the table below.
List Mode List mode
Run List Turn the list mode on/off.
On Turn the list mode on.
Off Turn the list mode off.
Recall List
Select a list program to view.
List Setup View the setting parameters of the selected list
program.
View Step Select the desired step to view.
Edit List
Edit list program.
Copyright © Itech Electronic Co., Ltd.