About the Product
Product and Component Identification
WARNING When replacing or repairing the ROPS/FOGS/TOPS structure you must replace the fixings.
Never re-use fixings. Use only new genuine JCB fixings tightened to the torque figures specified in the
operator's manual.
ROPS and TOPS Data Plate
Machines built to the ROPS (Roll-Over Protective Structure) and TOPS (Tip-Over Protective Structure)
standards have an identification label attached to the cab/canopy. Refer to Figure 6.
FOGS Data Plate
If the machine is used in any application where there is a risk of falling objects then a FOGS (Falling Object
Guard System) must be installed. For further information, contact your JCB dealer.
The FOGS has a data plate attached. The data plate indicates what level of protection the structure provides.
There are two levels of FOGS:
Level I Impact Protection- impact strength for protection from small falling objects (e.g. bricks, small
concrete blocks, hand tools) encountered in operations such as highway maintenance, landscaping and
other construction site services.
Level II Impact Protection- impact strength for protection from heavy falling objects (e.g. trees, rocks) for
machines involved in site clearing, overhead demolition or forestry.
Machine fitted with canopy, FOGS guard is integrated into canopy roof plate.
Level I FOGS guard only available with these machine. Refer to Figure 6.
9 9831/8250-4 9
JCB © Admin Pimteam - 23/06/2021 05:32.

Table of Contents

Other manuals for jcb 19C-1E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jcb 19C-1E and is the answer not in the manual?

jcb 19C-1E Specifications

General IconGeneral
Battery TypeManganese laminated Lithium-ion
Battery Rated Capacity14.8 kWh (3 Pack) 19.8 kWh (4 Pack)
ChargingOn-board charger with direct connection from AC mains power supply
Charging Time110V – 12 hrs 230V – 8 hrs
Fast Charging (Optional)Off-board charger, with connection to 415V 3-Phase supply Charging time <2 hrs
System Voltage48V
Motor TypeAC permanent magnet
Motor Power7 kW continuous 20kW peak
Operating ModesL – 1200rpm G – 1600rpm H – 1800rpm Auto Kick Up – 2300rpm, 2 speed tracking only
Thermal LimitationsOperation: -10oC to +46oC Charging: -10oC to +40oC