- 31 -
19. INITIALIZATION OF THE SETTING DATA
1) Keeping reset switch
1
and counter value
switch (+)
2
held simultaneously pressed, turn
the power ON. Then the screen is changed over
to the function setting data initialization screen.
2) When you press switch
3
, the process for
totally returning the function setting data to the
standard set values (initialization operation) is
executed.
3) Once the process is completed (approximately
one second later), the buzzer sounds (three
single tones, i.e., blip, blip, blip) and screen is
changed over to the power switch OFF notica-
tion screen.
Data on the function setting items can be returned to the standard set values.
[Function setting data initialization screen]
Do not run the power OFF during the ini-
tialization operation. It can damage the
program of the main body.)
1 2
3
4) Turn OFF the power switch to exit from the ini-
tialization.
[Power switch OFF notication screen]
1. The neutral point compensation value of the pedal sensor is also initialized by carrying out the
initialization operation. It is therefore necessary to carry out the automatic compensation of the
neutral point of the pedal sensor without exceptions before using the sewing machine.
(Refer to "18. Automatic compensation of neutral point of the pedal sensor" p. 30.)
2. The machine head angle adjustment value is also initialized by carrying out the initialization oper-
ation It is therefore necessary to carry out the machine head angle adjustment without exceptions
before using the sewing machine.
(Refer to "4. Sewing machine angle adjustment" p.3.)
3. Sewing data programmed on the operation panel are not initialized by carrying out the initializa-
tion operation.