- 33 -
■
Maintenance function screen
The time for needle changing, the time for cleaning and the time for oil changing can be set to continuously
display numeric values or display the notication after the lapse of preset time.
Refer to the Engineer's Manual for details.
2
4
3
[Explanation of the respective items]
2
Time of replacement of needle ..... Unit : X 1,000 stitches
3
Time of cleaning ............................ Unit : Hour
4
Time of replacement of oil ............. Unit : Hour
[Explanation of the contents of display]
(Numerator / denominator)
* Number of remaining stitches up to
*
thousand stitches /
**
thousand stitches
Example) Replacement of needle
100 / 1600
k
When
2
,
3
and
4
switches are pressed, the clear checking screen is displayed.
■
Clear screen
1
: The screen returns to the maintenance function screen without performing clearing.
2
: The screen returns to the maintenance function screen after executing clearing.
Time of replacement of needle is informed after 100 thousand stitches.
Time of replacement of needle is informed every 1,600 thousand stitches.
1
2