– 116 –
3) Enter the number of stitches with numeric key-
pad
.
Press
to conrm the setting.
Factory-set value at the time of delivery
: 0 (Number of stitches is not set)
Setting range : 0 to 200
* If this value is set to 0 (zero), the multi-layered
section changeover OFF function by the num-
ber of stitches will be disabled.
<Number of stitches to turn OFF the changeover function
when the one-touch changeover function is enabled>
After the end of multi-layered section of
material is fed, the multi-layered sec-
tion detection function detects the at
section of material to return the sewing
conditions to those for the at section.
However, this reaction sometimes delays
according to the sewing conditions.
If such a delay occurs, it can be correct-
ed by setting the number of stitches of
the multi-layered section detection.
After the sewing
machine has
nished sewing
of a multi-
layered section
of material,
the machine's
reaction is also
delayed by a
several number
of stitches.
End of a multi-
layered section
of material