4.2.1 Setting the charging characteristics (ELG 2430)
Z
The factory setting for trucks without a battery is the 0 position. A battery discharge
indicator, a charge/discharge indicator, a CanDis or a bipolar LED can be attached to
the connector (49).
CAUTION!
u
Remove the mains connector before setting the respective charging curve.
Set the charging characteristic
Requirements
– Battery connected.
Procedure
• Turn the setting switch (48) on the charger right to adapt the charging curve to the
battery being used.
• The validity of the new setting is acknowledged by the flashing of the green LED
and the setting takes immediate effect.
The charging characteristic is now set.
51
04.19 en-GB