4.2.2 Charging the battery
Starting to charge with the on-board charger
ELG mains connection
Mains supply: 230 V / 110 V (+10/-15%)
Mains frequency: 50 Hz / 60 Hz
The mains cable and the mains connector (17) of the battery charger are integrated
into the storage compartment in the dashboard panel.
Charge the battery
Requirements
Park the truck securely, see page 76.
Expose the battery, see page 46.
Correct charging program set on
charger.
Procedure
Remove any insulating mats from the
battery.
The battery connector must remain
plugged.
Attach the mains connector (17) to a
mains socket.
Pull the emergency disconnect switch
up.
The flashing LED indicates the charge status or a fault (for flashing codes see
“LED Display” table).
The battery is now charged.
17
Z
When the mains connector (44) is attached to the mains, all the truck’s electrical
functions are disconnected (electric immobilizer). The truck cannot be operated.