Charge Low Temperature Protection
Charge Low Temperature Release
Discharge Low temperature alarm
5°F ± 5.4°F (-15°C ± 3°C)
Discharge Low temperature protection
-4°F ± 5.4°F (-20°C ± 3°C)
Discharge Low temperature release
14°F ± 5.4°F (-10°C ± 3°C)
6.2. Warning / Alarm Indicators
Reduce the charging voltage or
stop charging
Stop discharging the battery.
Recharge within 15 days.
Stop charging or discharging
the battery until the battery
temperature falls below
recover temperature.
Stop charging or discharging
the battery until the battery
temperature rises above the
recover temperature
Charge or Discharge Over-
Current
Reduce the charging or
discharging current. The
battery will auto-release in one
minute.
Check the external power
connections of the battery.
Eliminate the short-circuit.
Flashing State of Charge Bar
The LCD control panel and/or
the State of Charge light bar
have lost connection to the
BMS. Restart the HAB™ using
the power button on the front
of the unit.