EasyManua.ls Logo

Kubota R430 - Shuttle Change Lever Operation; Travel Speed Switch

Kubota R430
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Do
not stop the engine by shutting down the
battery power directly with a battery switch or
by other means. Doing so may cause failure or
malfunction.
1. Idle the engine for about 5 minutes to allow it to
cool.
2. Slowly operate the control lever to place the bucket
on the ground.
3. Turn the starter key to the [STOP] position.
The engine stops.
STARTING THE ENGINE WITH
AN AUXILIAR
Y BATTERY
Follow the guidelines in this section when starting the
engine with an auxiliary battery
.
WARNING
T
o avoid personal injury or death:
Battery gases can explode.
Do not smoke and keep sparks and flames
away.
Do not start the engine with an auxiliary battery
if machine battery is frozen.
Do not connect the black jumper cable to the
negative (-) terminal of the machine battery.
1. Bring
the helping machine with the same battery
voltage as near as possible to the machine.
IMPORTANT :
The machines must not come in contact with
each other.
2. Bring the levers and pedal of both machines in the
neutral position.
3. Wear eye protection and rubber gloves.
4. Make sure that the vent caps are securely in place
if equipped.
5. Connect the terminal of the red jumper cable with
the plus (+) terminal of the low battery and connect
the other end of the cable to the plus (+) terminal of
the auxiliary battery.
6. Connect the black negative cable to the minus (-)
terminal of the auxiliary battery.
7. Connect the other end of the black cable coming
from the auxiliary battery to the conductive part of
the machine frame as far away as possible from the
low battery.
8. Start the engine of the helping machine and let it
run for a while.
9. Start the machine with the low battery.
10. Disconnect the jumper cables in the reverse
sequence.
(1) Low battery
(2)
Auxiliary battery
(3) Jumper cables
IMPORTANT :
This
machine equips a negative (-) ground
12 Volt starting system.
Only use the same voltage when using an
auxiliary battery.
Using a higher voltage will cause serious
damage to the electrical system. When using
an auxiliary battery, only the compatible
(same) voltage is permissible.
STARTING THE ENGINE WITH AN AUXILIARY BATTERY  OPERATION OF THE ENGINE
R430
43

Table of Contents

Related product manuals