75PERIODIC SERVICE
[RTV-X900]
[RTV-X1120D]
C Precaution at Overheating
Take the following actions in the event the coolant
temperature is close to or more than the boiling point,
which is called "Overheating".
1. Stop the vehicle operation in a safe place, unload the
engine and remain at idle.
2. Don't stop the engine suddenly, but stop it after about
5 minutes of unloaded idling.
3. Keep yourself well away from the vehicle for at least 10
minutes or while the steam is blowing out.
4. Check to confirm that there is no danger from the
overheat condition, check the
"TROUBLESHOOTING" section to determine the
cause of the overheat and fix the cause. After the
engine has cooled, re-start the engine.
BChecking Intake Air Line
1. Check to see if the hoses and hose clamps are tight
and not damaged.
2. If hoses and clamps are found to be worn or damaged,
replace or repair them at once.
(1) Radiator hose
(2) Clamp band
(A) Oil cooler
(1) Radiator hose
(2) Clamp band
(1) Radiator hose
(2) Clamp band
(1) Hose
(2) Hose clamp
(1) Hose
(2) Hose clamp