Configuration of analog and digital setpoints and actual values
Setpoints via a bus system
10
Function library
10.8
10.8.7
L
10.8-16
EDS82EV903-1.0-11/2002
With keypad XT EMZ9371BC
The setpoint can be directly selected under C0140:
1. Select C0140 in the menus.
2. Set the setpoint using y or z
Drive performance
l If the controller is enabled, the changed setpoint has a direct effect on the
drive.
l The setpoint is saved when the controller is inhibited. After the controller
has been enabled, the drive accelerates or decelerates to the saved value.
l The setpoint selected via keypad has an effect on setpoint 1 (NSET1-N1)
and setpoint 2 (NSET1-N2). If you want to select different setpoints via
keypad:
– Separate the linkage of NSET1-N1 and NSET1-N2 with analog input
signals (C0412/1 = 0 and C0412/2 = 0).
– Now you can set NSET1-N1 in C0046 and NSET-N2 in C0044 with the
keypad.
l Set C0140 = 0, if the setpoint is not given under C0140, otherwise the drive
may start immediately when the controller is released.
10.8.7 Setpoints via a bus system
Setpoints or actual values can be preselected for FIF by means of a bus function
module or AIF by means of a bus module.
A detailed description can be found in the documentation for the modules.
Setpoint selection with keypad
XT EMZ9371BC
Drive performance when
selecting the setpoints via
keypad
Tip