EasyManuals Logo
Home>Lenze>DC Drives>E82EV302K4C

Lenze E82EV302K4C User Manual

Lenze E82EV302K4C
588 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #535 background imageLoading...
Page #535 background image
Speed control
15
Application examples
15.5
L
15.5-1
EDS82EV903-1.0-11/2002
15.5 Speed control
)
))
) Note!
Lenze three-phase AC motors and Lenze geared motors are
available with Lenze pulse encoder ITD21 (512/2048 increments,
HTL output signals). This enables a two-tracked speed feedback
(tracks A and B)to be built up:
l With Application I/O function module: 0 ... 100 kHz
l With Standard I/O function module: 0 ... 1 kHz
Speed control with inductive, single-tracked 3-conductor sensor
The speed control is to compensate the difference between actual speed and
speed setpoint caused by load (motor and generator mode).
The motor speed is detected by an inductive sensor (e.g. gear, metallic fan wheel,
cam). The sensor can detect the speed either directly at the motor or in the
machine.
6 2 8 9
7
2 0 2 8 E 1
A 1
E 4E 3E 2 3 9
+ 5 V
G N D 2
8 2 0 0
M
3 ~
3
7
5 9
G N D 1
+ 2 0 V
G N D 1
Q
R
S t a n d a r d - I / O
Fig. 15.5-1 Speed control with 3-conductor sensor

Setpoint

3-conductor sensor
8200
8200 mot e c or 8200 vector
Example

Table of Contents