Technical Data
3-4 821XKlimaBA0399
3.2.3 Types 8215 to 8218
120 % overload Type 8215 8216 8217 8218
Order no. EVF8215-E-
V020
EVF8216-E-
V020
EVF8217-E-
V020
EVF8218-E-
V020
Mains voltage V
rated
[V] 320 V - 0%
$
V
rated
$
440 V + 0%; 45 Hz
¡
65 Hz
á
0%
Alternative DC supply V
DC
[V] 450 V - 0%
$
V
DC
$
620 V + 0%
Mains current
with mains filter/mains choke
I
mains
[A] 12.0 12.0 20.5 20.5
Data for mains operation with 3 AC/400 V/50 Hz/60 Hz; 450 V
$
V
DC
$
650 V
Motor power (4 pole ASM)
P
rated
[kW] 5.5 5.5 11.0 11.0
off 4kHz/8kHz*
P
rated
[hp] 7.5 7.5 15.0 15.0
Output power U, V, W
off 4 kHz/8 kHz*
S
rated4
[kVA] 9.0 9.0 16.3 16.3
Output power +U
G
,-U
G
1)
P
DC
[kW] 0.7 0.0 1.0 0.0
Output
4kHz* I
rated4
[A] 13.0 13.0 23.5 23.5
8kHz* I
rated8
[A]
Max.
output
4kHz* I
rated max4
[A] 14.1 19.5 24.8 35.3
for 60s
2)
8kHz* I
rated max8
[A]
Motor voltage
3)
V
M
[V] 0-3
V
mains
/0Hz
¡
50Hz, if required up to480Hz
Power loss (Operation with I
Nx
) P
v
[W] 200 200 400 400
Power derating [%/K]
[%/m]
40
C<T
amb
<50
C: 2.5%/K
1000 m amsl
h
$
4000 m amsl: 5%/1000m
Field
Resolution absolute 0.02 Hz
freque
ncy
Digital setpoint
selection
Accuracy
á
0.05 Hz
Analog setpoint
Linearity
á
0.5 %(max. selected signal level: 5 V or 10 V)
selection
Temperature
sensitivity
0
¡
40
C: +0.4 %
Offset
á
0%
Weight m[kg] 5.3 5.3 5.3 5.3
1)
This power can be additionallyobtained when operating a matching motor
2)
The currents applyto a periodical load cycle with 1 minute overcurrent with the current mentioned here
and 2 minutes base load with75%I
Nx
.
3)
With mains choke/mains filter: max. output voltage = approx. 96 % of the mains voltage