Table 6-1. Factory Preset EDID list
Info The F01..F20 EDIDs are factory preprogrammed and cannot be modified. These are the
most commonly used resolutions.
6.10. Learning the EDID
The factory preset EDIDs cannot be changed by the user. Only addresses #6 .. #9 (on
any rotary switches) are user programmable.
Important! EDID learning is only available from the active input to a user memory location which was
selected by a rotary switch. EDID learning is not allowed in AUTOSELECT mode.
Info: Before a digital EDID will be selected to an analog output port UMX-OPT-TX150R
removes the digital descriptor from the EDID and selects it.
After connecting the sink device to the unit’s output (for example the receiver unit’s
HDMI OUT), use a screwdriver to select an empty memory address. EDIDs are stored in
a multiple programmable non-volatile memory.
Push the LEARN button on the front side of the device and hold it down for approximately
3 seconds.
If the EDID storing was successful on the active port, the EDID LED blinks 3 times in 3
seconds slowly then they return to their original function.
If the storing was unsuccessful on the active port, the EDID LED blinks 3 times in 1
second quickly then they return to their original function.
Info: The last attached monitor’s EDIDs are stored automatically, until a new monitor is
attached to the output (or receiver’s output). In case of powering the unit off, the last
attached monitor’s EDID remains in non-volatile memory.
Info: As a matter of fact UMX-OPT-TX150R always learns the stored last attached monitor’s
EDID into the user programmable EDID memory. If the attached sink device on the
output is unplugged pushing and holding the LEARN EDID button causes a successful
EDID learning without plugging in the monitor again (even after a power reset).