5-4 Published 3-25-2020, Control # 643-04
MAINTENANCE AND LUBRICATION GRT880 OPERATOR MANUAL
Arctic Lubricants and Conditions
Temperatures Below -9°C (15°F)
Regions with ambient temperatures below -9°C (15°F) are
considered arctic. In general, petroleum based fluids
developed especially for low temperature service may be
used with satisfactory results in these temperatures.
However, certain fluids, such as halogenated hydrocarbons,
nitro hydrocarbons, and phosphate ester hydraulic fluids,
may not be compatible with hydraulic system seals and wear
bands. Always check with an authorized Grove distributor or
Manitowoc Crane Care if in doubt of the suitability of a
specific fluid or lubricant.
When operating in cold weather and regardless of the oil
viscosity of the crane’s lubricants, always follow the cold
weather start-up and operating procedures described in the
Operator Manual to ensure adequate lubrication during
system warm-up and proper operation of all crane functions.
Cold Weather Package and Lubricants
Grove recommends the following cold weather lubricants for
use with ambient temperatures down to -29°C (-20°F)
(TABLE 5-2) and -40°C (-40°F) (TABLE 5-3). But, these cold
weather lubricants alone are not sufficient to operate the
crane in extreme low temperatures. Therefore, it is also
recommended that the crane be equipped with the following
accessories:
Down to -29°C (-20°F) Package
Battery heater
Fuel line heater
Engine hood insulation
Fan clutch
Radiator air shutters
Air diverter
Diesel fired cab heater
Cold weather alternator
Fluids suitable to -29°C (-20°F)
- Arctic windshield washer fluid
- Arctic fuel
Down to -40°C (-40°F) Package
Coolant heaters (to circulate warm coolant through
heaters and engine)
Fuel line heaters
Transmission heater
Battery heater
Engine hood insulation
Fan clutch
Radiator air shutters
Air diverter box (to allow intake air to be taken in from
under the engine hood)
Diesel fired cab heater
Cold weather alternator
Super-capacitor starting system
Fluids suitable to -40°C (-40°F)
- Arctic windshield washer fluid

Table of Contents

Other manuals for Manitowoc Grove GRT880

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GRT880 and is the answer not in the manual?

Manitowoc Grove GRT880 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GRT880
CategoryConstruction Equipment
LanguageEnglish

Related product manuals