5-26 Published 3-25-2020, Control # 643-04
MAINTENANCE AND LUBRICATION GRT880 OPERATOR MANUAL
Hoist
Item
Lube Point
Description
Figure No.
Approved
Lubricant
Lube
Capacity
Lube Interval Application
100 Main Hoist Figure 5-15 B
4.7 L
(5 qt)
• Check and fill every
50 hours or weekly
• Drain and fill every
1000 hours or 12
months
Oil must be visible in
sight glass and level no
more than 3 mm
(0.13 in) from top of
sight glass.
101 Auxiliary Hoist Figure 5-15 B
4.7 L
(5 qt)
• Check and fill every
50 hours or weekly
• Drain and fill every
1000 hours or 12
months
Oil must be visible in
sight glass and level no
more than 3 mm
(0.13 in) from top of
sight glass.
NOTE: Line up Fill/Drain Plug with upper access hole (A). Let hoist sit idle for 20 minutes for an accurate reading. If oil
level is not visible in sight glass, hoist is under filled. Oil escaping from vent plug (B) or more than 3 mm (0.13 in)
from top of sight glass is an indication hoist is overfilled. If hoist is over filled, drain oil from the Fill/Drain Plug at the
upper access hole. When replacing oil, align Fill/Drain Plug with lower access hole (C) and drain oil.
Failure to align Fill/Drain Plug with upper access hole before checking oil level will result in an inaccurate reading.
102 Cable Roller Figure 5-15 A
Thoroughly
coat.
250 hours or 3 months. Brush on.
103 Hoist Bearing Figure 5-15 A
Until grease
extrudes.
250 hours or 3 months. 2 grease fittings.
NOTE: Lubricate more frequently than interval indicated if environmental and/or operating conditions required.
FRONT
FRONT
102
102
100
101
103
103
FIGURE 5-15
8618
8619