Grove Published 3-25-2020, Control # 643-04 5-9
GRT880 OPERATOR MANUAL MAINTENANCE AND LUBRICATION
5
Drive Train
Item
Lube Point
Description
Figure
No.
Approved
Lubricant
Lube
Capacity
Lube Interval Application
1 Air Cleaner Filter Figure 5-1 --- ---
Replace filter element
when indicator shows red.
2 Fuel Filter Figure 5-1 --- ---
Change filter every 500
hours or 6 months.
Fuel filter is located
on inside right hand
side of frame beside
engine.
3
Engine
Crankcase Tier 3
Figure 5-1 F
20 L
(21 qt)
Check level every 10
hours or daily.
Drain, fill and replace
filter every: 500 hours
(0-500 ppm sulfur fuel);
400 hours
(500-5000 ppm sulfur
fuel); 250 hours
(>5000 ppm sulfur fuel)
Through fill cap to
FULL mark on
dipstick.
3
Engine
Crankcase Tier 4
Figure 5-1 F
20 L
(21 qt)
Check level every 10
hours or daily.
Drain, fill and replace
filter every 500 hours.
Through fill cap to
FULL mark on
dipstick.
4
Engine Cooling
System and SCA
Levels
Figure 5-1 C, D
52.7 L
40 qt
Check coolant level
every 10 hours or daily.
Check SCA levels
every 500 hours.
Check coolant for
contamination every
1000 hours.
Check level in
sight glass at
rear of crane.
Superstructure
must be rotated
to access filler
on top of carrier.

Table of Contents

Other manuals for Manitowoc Grove GRT880

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GRT880 and is the answer not in the manual?

Manitowoc Grove GRT880 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GRT880
CategoryConstruction Equipment
LanguageEnglish

Related product manuals