Technical Information
36
CVA615 Coffee System
4.20.1 Water Intake
The Pump takes in water from the water tank. (The Pump is fitted
with a safety valve which opens at approx. 16 bar (232 psi) system
pressure. If the pressure is too high and the safety valve opens,
water is drained off via a hose to the drip tray).
4.20.2 Water Path - Coffee
The water is then pumped under pressure through the Flowmeter,
and through the Coffee Flow Through Heater. The water is then
passed through the Water Valve, into the Brew Unit.
4.20.3 Water Path - Hot water
The Pump moves water under pressure through the Flowmeter,
and through the Coffee Flow Through Heater. The water is then
passed via the Hot Water Valve to the Hot Water Outlet.
4.20.4 Water Path - Steam
The pump moves water under pressure via the Flowmeter and
through the Coffee Flow Through Heater. When the user selects
steam; the Electronic energizes the Steam Valve. Water continues
flowing through the Steam Flow Through Heater. Steam is then
dispensed from the frothing nozzle.

Table of Contents

Other manuals for Miele CVA615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miele CVA615 and is the answer not in the manual?

Miele CVA615 Specifications

General IconGeneral
BrandMiele
ModelCVA615
CategoryCoffee Maker
LanguageEnglish

Related product manuals