Technical Information
22
T1500 Series Clothes Dryers
4.4 Residual Moisture Sensing
There are two variables that determine the Dryer run time; initial
moisture content in the laundry and the program selected.
At the beginning of the cycle, the moisture content within the
laundry is measured by the Residual Moisture Sensor. This value is
used by the electronic to calculate the approximate program
duration.
During drying, the level of moisture within the laundry decreases.
And is reflected by the status of the Drying Stage Reached LED’s.
When the moisture within the laundry reaches the selected program
value the Dryer enters the cooling down stage, followed by the
Anti-Crease mode.
Important
The electronic limits all moisture sensing programs to a maximum
duration of 240 minutes. Should 240 minutes be reached, the
cooling down stage is initiated; however the Anti-Crease feature is
skipped when this occurs.
The Cooling Down LED remains illuminated until the appliance is
shut off - via the On/Off Button.