F3Ci Service Manual
_______________________________________________________________________________________________________________________
25
•
Identify the ribbon cable connector on the main PCB which connects to the switches.
•
Lift open the locking bails on the ribbon cable connector this allows the ribbon cable
to be removed and inserted.
•
Gently slide the ribbon cable out of the connector.
•
Slide the main PCB away from the battery assembly until the ends of the main PCB
disengage from the slots in the detector body near the battery compartment.
Figure 33: Disconnect Connectors on main PCB