F3Ci Service Manual
_______________________________________________________________________________________________________________________
25
Identify the ribbon cable connector on the main PCB which connects to the switches.
Lift open the locking bails on the ribbon cable connector this allows the ribbon cable
to be removed and inserted.
Gently slide the ribbon cable out of the connector.
Slide the main PCB away from the battery assembly until the ends of the main PCB
disengage from the slots in the detector body near the battery compartment.
Figure 33: Disconnect Connectors on main PCB
Figure 34: Disconnect the Ribbon Cable
Earset Cable
A
ssembly
internal
Wiring Loom Handle
Vibration Motor
Connector
1. Identify Ribbon Cable
3. Remove Ribbon Cable
2. Open Locking Bail