F3Ci Service Manual
_______________________________________________________________________________________________________________________
51
3.8.1
Battery Lid Replacement
a. Open the detector body as described in Section 3.1 - Opening the Detector Body. Once
completed:
N
ote
The battery lid can be replaced without opening the detector body if the tether is unscrewed from
the battery lid.
•
Check the battery lid has an O-ring correctly in place. The O-ring must be clean and
can be lightly greased.
•
Check the battery lid closes onto the battery compartment. Fit and close the battery
lid.
b. Close the detector body as described in Section 3.2 - Closing the Detector Body.
3.8.2
Battery Compartment Replacement
a. Open the detector body as described in Section 3.1 - Opening the Detector Body. Once
completed:
•
Disconnect the battery connector. Figure 87.
•
Remove the two screws (12mm) from the battery compartment.
•
Slide the battery compartment rearward (away from the main PCB), threading the
battery connector out of the detector body.
•
Refit the battery compartment by first feeding the battery connector through the
hole in the detector body.
•
Slide the battery compartment into position.
•
Connect the battery connector.
•
Refit the two mounting screws (12mm).
•
Close and lock the battery lid.
b.
Reassemble the detector by closing the detector body as described in Section 3.2 -
Closing the Detector Body.
Battery Connector
Figure 87: Replacing Battery Compartment