F3Ci Service Manual
_______________________________________________________________________________________________________________________
33
Insert a flat tip screwdriver into the slot underneath the cap shaft and lift and
remove the cap shaft.
Slide the coil out and off the lower shaft, exposing the coil cable.
Push the coil cable connector into the shaft hinge whilst gently pulling the coil cable
out of the end of the lower shaft. Once the coil connector has passed through the
shaft hinge it should slide out easily from the shafts. Do not force the coil cable or
coil connector.
b.
The coil can now be removed or replaced as required. To fit the coil to the detector refer
to section 3.4.6 - Fitting the Coil.
3
.4.3
Coil Pivot.
a.
The coil pivot is a line replaceable unit and Figure 55 illustrates the major parts. Each part
of the coil pivot can be ordered individually or as a 3004-0130 Coil Pivot Kit which includes all
parts shown in Table 3.
Figure 50: Sliding the Coil Off the Shaft
Figure 49: Removing Screws from Lower Shaft
Figure 5
1
:
Coil Assembly.