Remove the pin coil cable from the upper end of the upper shaft. Turn the pin coil
cable clock wise and then lift out.
Remove the two nylon screws from the cap shaft on the lower shaft as indicated in
Figure 74.
Insert a flat tip screwdriver into the slot underneath the cap shaft and lift and
remove the cap shaft.
Slide the coil out and off the lower shaft, exposing the coil cable. Feed the coil cable
connector into the upper shaft and pull the coil cable out of the end of the lower
shaft. Figure 75
Figure 73: Removing Pin Coil Cable
Figure 72: Shaft and Coil removed from Detector
Figure 74: Removing Screws from Lower Shaft