32
33
󰽍
Control pressure adjust
Set the control pressure when connecting the outdoor air conditioning unit to
the Multi (KX) System.
Standard: Normal
Type 1: When all operating IUs are in this mode, the control pressure
value is changed.
󰽌
Fan circulator operation
Set this when operating the fan as a circulator.
Disable: During the fan operation, the fan runs continuously.
Enable: During the fan operation, the fan runs and stops based on the
difference between temperatures detected with the R/C sensor
and the return air sensor.
󰽋
Intermittent fan operation in heating
Select the fan control after the residual fan operation following stop and
thermo-OFF in heating mode.
Stop: Intermittent fan operation is not done.
Stop for 20 min and run for 5 min:
Check the operating conditions at every 25 min
and run the fan for 5 min.
Stop for 5 min and run for 5 min:
Check the operating conditions at every 10 min
and run the fan for 5 min.
󰽋
Intermittent fan operation in heating
󰽌
Fan circulator operation
󰽍
Control pressure adjust
󰽊
Residual fan operation in heating
Select the residual fan operation time period after stopping and the thermo-
OFF in heating mode.
Setting1: 0.5 hr
Setting2: 2 hrs
Setting3: 6 hrs
󰽊
Residual fan operation in heating

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries eco touch RC-EX1A and is the answer not in the manual?

Mitsubishi Heavy Industries eco touch RC-EX1A Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
Modeleco touch RC-EX1A
CategoryRemote Control
LanguageEnglish

Related product manuals