CHASSIS ELECTRICAL – General / Battery
54-3
GENERAL
Outline of Change
D The following service procedures have been incorporated.
BATTERY
SERVICE SPECIFICATION
Item Specification
Specific gravity of the battery fluid 1.220–1.290 [20_C]
ON-VEHICLE SERVICE
FLUID LEVEL AND SPECIFIC GRAVITY CHECK
1. Inspect whether or not the battery fluid is between the
UPPER LEVEL and LOWER LEVEL marks.
2. Use a hydrometer and thermometer to check the specific
gravity of the battery fluid.
Standard value: 1.220–1.290 [20_C]
The specific gravity of the battery fluid varies with the
temperature, so use the following formula to calculate
the specific gravity for 20_C. Use the calculated value
to determine whether or not the specific gravity is
satisfactory.
D
20
=Dt+0.0007 (t–20)
D
20
: Specific gravity of the battery fluid calculated
for 20_C.
Dt: Actually measured specific gravity
t: Actually measured temperature
Ther-
mometer
Hydrometer
Good