Chapter 6 Troubleshooting
SCV-series Screw Compressors
6-3
Trouble Direct causes Factors Actions
04
Low
oil-supply
pressure
pressure detection
divices.
hydraulic pressure
protection
device(switch),
pressure sensor,
Identify malfunctioning devices,
examine their causes, and take
measures.
Then, replace malfunctioning
devices.
tubing for oil
pressure protection
Remove clogging. Check oil
contamination level and replace oil
as necessary.
high
pressure
(abnormal
discharge
pressure)
failure at condenser
(heat exchanger)
blocked heat
exchanger tubes,
Use solvent to clean depending on
contamination.
motor,
thermo-switch,
water spray bars,
cooling water
pumps, etc.
(including shortage
Identify malfunctioning devices,
examine their causes, and take
measures.
Then, replace malfunctioning
devices.
adjustment failure
of cooling water,
brine, etc.
If regulating valve is manually
adjusted, readjust it.
If an automatic control valve
(including wax valve) is used,
examine its cause and take
insufficient
circulation volume
of cooling water,
etc.
contamination of filters for
circulation route filters, and take
measures as needed.
Inspect for leak in circulation routes,
and take measures if any.
Inspect water supply routes and
systems, and take measures as
needed. If frozen, resolve by better
capacity of heat
exchanger.
If the trouble is caused by change in
operating conditions, re-examine
the conditions to improve.
If the trouble is caused by change in
installation environment, improve
the environment if possible.
For both cases, if it is difficult to
improve, add more heat exchanger
in the system
pressure side
through pinholes,
cracks, corrosions
and other defective
Inspect for leak, and take necessary
measures.
Then, air purge the heat exchanger.