© National Instruments | 3-5
X Series User Manual
+5 V Power Source
The +5 V terminals on the I/O connector supply +5 V referenced to D GND. Use these terminals
to power external circuitry.
Caution Never connect the +5 V power terminals to analog or digital ground or to
any other voltage source on the X Series device or any other device. Doing so can
damage the device and the computer. NI is not liable for damage resulting from such
a connection.
The power rating on most devices is +4.75 VDC to +5.25 VDC at 1 A.
Refer to the device specifications to obtain the device power rating.
Note (PCI Express X Series Devices) Some PCI Express X Series devices
supply less than 1 A of +5 V power unless you use the disk drive power connector.
Refer to the
PCI Express Device Disk Drive Power Connector section for more
information.
USER 1 and USER 2
The USER 1 and USER 2 BNC connectors allow you to use a BNC connector for a digital or
timing I/O signal of your choice. The USER 1 and USER 2 BNC connectors are routed internally
to the USER 1 and USER 2 screw terminals, as shown in Figure 3-1.
Figure 3-1. USER 1 and USER 2 BNC Connections
USER 2 BNC
D GND
AI SENSE
AI GND
+5 V
D GND
USER 2
USER 1
CHS GND
AI SENSE 2
APFI 0
Internal
Connection
USER 1 BNC
D GND
Screw
Terminal
Block

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments 636 Series and is the answer not in the manual?

National Instruments 636 Series Specifications

General IconGeneral
BrandNational Instruments
Model636 Series
CategoryData Loggers
LanguageEnglish

Related product manuals