Figure 19. Mounting the 8-slot cRIO-904x Directly on a Flat Surface
1
2
3
1. Prepare the surface for mounting the cRIO-904x using the Surface Mounting
Dimensions .
2. Align the cRIO-904x on the surface.
3. Fasten the cRIO-904x to the surface using the M4 screws appropriate for the surface.
Screws must not exceed 8 mm of insertion into the cRIO-904x. Tighten the screws to a
maximum torque of 1.3 N · m (11.5 lb · in.).
Surface Mounting Dimensions
The following figures show the surface mounting dimensions for the 4-slot and 8-slot
cRIO-904x models.