Chapter 2 Analog Input
E Series User Manual 2-4 ni.com
–10 to +10 V
–5 to +5 V
–2.5 to +2.5 V
–1 to +1 V
–500 to +500 mV
–250 to +250 mV
–100 to +100 mV
–50 to +50 mV
0.5
1
2
5
10
20
50
100
Bipolar 4.88 mV
2.44 mV
1.22 mV
488 µV
244 µV
122 µV
48.8 µV
24.4 µV
4.88 mV
2.44 mV
1.22 mV
488 µV
244 µV
122 µV
48.8 µV
24.4 µV
305 µV
153 µV
76.3 µV
30.5 µV
15.3 µV
7.63 µV
3.05 µV
1.53 µV
4.88 mV
2.44 mV
1.22 mV
488 µV
244 µV
122 µV
48.8 µV
24.4 µV
4.88 mV
2.44 mV
1.22 mV
488 µV
244 µV
122 µV
48.8 µV
24.4 µV
Table 2-2. Input Ranges for NI 6011E and NI 6030E/6031E/6032E/6033E
Input Range Gain Polarity
Precision
NI 6011E
NI 6030E/6030E/
6032E/6033E
0 to +10 V
0 to +5 V
0 to +2 V
0 to +1 V
0 to +500 mV
0 to +200 mV
0 to +100 mV
1
2
5
10
20
50
100
Unipolar 153 µV
76.3 µV
—
15.3 µV
—
—
1.53 µV
153 µV
76.3 µV
30.5 µV
15.3 µV
7.63 µV
3.05 µV
1.53 mV
–10 to +10 V
–5 to +5 V
–2 to +2 V
–1 to +1 V
–500 to +500 mV
–200 to +200 mV
–100 to +100 mV
1
2
5
10
20
50
100
Bipolar 305 µV
153 µV
—
30.5 µV
—
—
3.05 µV
305 µV
153 µV
61.0 µV
30.5 µV
15.3 µV
6.10 µV
3.05 µV
Table 2-1. Input Ranges for NI 6020E, NI 6040E, NI 6052E, NI 6062E, and NI 6070E/6071E (Continued)
Input Range Gain Polarity
Precision
NI 6020E NI 6040E NI 6052E NI 6062E
NI 6070E/
6071E