© National Instruments | 2-5
RMC-8356 User Manual
Boot Feature
Quiet Boot
Use this feature to select the screen display between the POST messages and the OEM logo upon
bootup. Select Disabled to display the POST messages. Select Enabled to display the OEM logo
instead of the normal POST messages. The options are Enabled and Disabled.
AddOn ROM Display Mode
Use this feature to set the display mode for the Option ROM. Select Keep Current to display
the current AddOn ROM setting. Select Force BIOS to use the Option ROM display set by
the system BIOS. The options are Force BIOS and Keep Current.
Bootup NumLock State
Use this feature to set the Power-on state for the <Numlock> key. The options are Off and On.
Wait For “F1” If Error
Use this feature to force the system to wait until theF1 key is pressed if an error occurs.
The options are Disabled and Enabled.
INT19 (Interrupt 19) Trap Response
Interrupt 19 is the software interrupt that handles the boot disk function. When this item is
set to Immediate, the ROM BIOS of the host adapters will capture Interrupt 19 at bootup
immediately and allow the drives that are attached to these host adapters to function as
bootable disks. If this item is set to Postponed, the ROM BIOS of the host adapters will not
capture Interrupt 19 immediately and allow the drives attached to these adapters to function as
bootable devices at bootup. The options are Immediate and Postponed.
Re-try Boot
If this item is enabled, the BIOS will automatically reboot the system from a specified
bootdevice after its initial boot failure. The options are Disabled, Legacy Boot, and EFI Boot.
Power Configuration
Watch Dog Function
If enabled, the Watch Dog Timer will allow the system to reset or generate NMI based on
jumper settings when it is expired for more than 5 minutes. The options are Enabled and
Disabled.
Power Button Function
This feature controls how the system shuts down when the power button is pressed. Select
4_Seconds_Override for the user to power off the system after pressing and holding the power
button for 4 seconds or longer. Select Instant Off to instantly power off the system as soon as
the user presses the power button. The options are 4 Seconds Override and Instant Off.

Table of Contents

Other manuals for National Instruments RMC-8356

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments RMC-8356 and is the answer not in the manual?

National Instruments RMC-8356 Specifications

General IconGeneral
BrandNational Instruments
ModelRMC-8356
CategoryController
LanguageEnglish

Related product manuals