6
BATTERY LED
FLASHING LIGHT 24Vcc
2
POWER INPUT
MAINS
1
ENCODER
MOTOR
LINE EARTH
MOTOR EARTH
Max 25W
5
3
4
8
9
7
6
M
19
COR
PHOTOTEST 24 Vcc
Max 200mA
Max 500 mA
ELECTRIC BLOCK 24Vcc
SERVICES 24 Vcc
SCA
COMMON 24Vcc
Max 200mA
14
12
11
13
10
18
16
15
17
PHOTO 2
MAN
PARTIAL OPEN
OPEN
CLOSE
PHOTO
STOP
STEP BY STEP
24
23
20
21
22
27
26
25
F1
BATTERY
ENCODER LED
RELEASE LED
STEP BY STEP
CLOSE
PARTIAL OPEN
PHOTO2
PHOTO
STOP
OPEN
44
2ND RADIO CHANNEL
AERIAL
42
41
43
2.3) Electrical connections
To protect the operator and avoid damaging the com-
ponents while electrical connections are being made or
the radio receiver is being connected, the control unit
may not be mains and/or battery powered
To make connections, please consult the electrical dia-
gram (paragraph 2.4), bearing in mind that:
The control unit must be powered with a 3 x 1.5mm
2
cable (phase,
neutral and earth); should the distance between the unit and the earth
connection exceed 30 m, an earth plate must be fitted near the unit
For connections to SUMO, a 3x2.5 mm
2
cable must be used (if over
10m long, use 4mm
2
) for the motor and a 2 x 0.75mm
2
cable for the
encoder
Use a cable with a minimum cross-section of 1 mm
2
to connect the
flashing light and the electrical block
Wires with a minimum cross section of 0.25 mm
2
must be used to
connect very low voltage safety circuits; (use shielded wires if the
length exceeds 30 m and connect the earth braid at the control unit
end only)
Maximum attention should be paid to polarised equipment (flashing
lamp, electric block, phototest output, services, battery, etc).
If the inputs of the Normally Closed (NC) contacts are not used they
should be jumped with the “24Vdc Common” terminal; if the
Normally Open (NO) inputs are not used they should be left free.
The contacts must be mechanical and potential-free; no stage
connections are allowed, such as those defined as "PNP", "NPN",
"Open Collector", etc.
!
2.4) Electrical diagram