GB
7
2.5) Description of connections
Terminals Functions Description
1-2 Phase - Neutral Mains power input
3 Earth Control unit earth connection
4 Earth Motor earth connection
5-6 Motor 36Vdc motor power input
7-8 Encoder Motor encoder input
9-10 Flashing lamp 24Vdc flashing lamp input max. 25W
11-12
Electrical block/Suction pad
24Vdc electrical block/suction pad output max. 500mA
13-14 Phototest Phototest output
15-16 24Vdc 24Vdc services power input max. 200mA
17 Common Common for all inputs
18 Sca Door open lamp output (on when the door is open, off when it is closed, flashes
slowly during the opening manoeuvre, flashes quickly during the closing manoeuvre)
19 Cor Courtesy lamp output (switches on when the manoeuvre begins and switches off 60
seconds after the manoeuvre has finished)
20 Man Maintenance lamp output
21 Stop Input with STOP function (Emergency, shutdown or extreme safety)
22 Photocell Input for safety devices (photoelectric cells, pneumatic edges) affecting the closing
manoeuvre
23 Photo 2 Input for safety devices (photoelectric cells, pneumatic edges) affecting the opening
manoeuvre
24 Step-by-step Input with cyclical Open-Stop-Close-Stop operation
25 Open Input for opening movement with cyclical Open-Stop-Open-Stop operation
26 Close Input for closing movement with cyclical Close-Stop-Close-Stop operation
27 Partial open Input with cyclical Partial Open - Stop - Close- Stop operation
41-42 2° Radio Ch Output for the second radio receiver channel
43-44 Aerial Input for the radio receiver aerial
+ - Battery 24 volt battery connection