The length of the leaf makes it possible to determine both the maximum number of cycles per hour and consecutive cycles, while the weight
makes it possible to determine the reduction percentage of the cycles and the maximum speed allowed. For example, for ROBUS 1000 if
the leaf is 5 m long it will be possible to have 33 cycles/hour and 16 consecutive cycles. However, if the leaf weighs 700 Kg, they must be
reduced to 50%, resulting in 16 cycles/hour and 8 consecutive cycles, while the maximum speed allowed is V4: fast. The control unit has a
limiting device which prevents the risk of overheating based on the load of the motor and duration of the cycles. This device triggers when
the maximum limit is exceeded. The manoeuvre limiting device also measures the ambient temperature reducing the manoeuvre further when
the temperature is particularly high.
The “durability” estimate is shown in chapter 8 “Technical characteristics”, which is the average useful life of the product. The value is deeply
influenced by the severity index of the manoeuvre, this being the sum of all factors that contribute to wear. To perform this estimate, all sever-
ity indexes in table 4 must be totalled, then the estimated durability in the graph must be checked with the total result.
For example, when ROBUS 1000 is fitted to a gate weighing 650 Kg and 5m in length, equipped with photocells and without other stress
related elements, it obtains a severity index equal to 50% (30+10+10). From the graph the estimated durability is equal to 80,000 cycles.
RB600, RB600P RB1000, RB1000P
Leaf weight (kg) % cycles Maximum speed % cycles Maximum speed
allowed allowed
Up to 200 100% V6 = Extremely fast 100% V6 = Extremely fast
200 ÷ 400 80 V5 = Very fast 90 V5 = Very fast
400 ÷ 500 60 V4 = Fast 75 V4 = Fast
500 ÷ 600 50 V3 = Medium 60 V4 = Fast
600 ÷ 800 --- --- 50 V3 = Medium
800 ÷ 900 --- --- 45 V3 = Medium
900 ÷ 1000 --- --- 40 V3 = Medium
Table 3: limits in relation to the weight of the leaf
Table 4: durability estimate in relation to the manoeuvre severity index
Severity index % Robus Durability in cycles
600 1000
Leaf weight Kg
Up to 200 10 5
200 ÷ 400 30 10
400 ÷ 600 50 20
600 ÷ 700 --- 30
700 ÷ 800 --- 40
800 ÷ 900 --- 50
900 ÷ 1000 --- 60
Leaf length m
Up to 4 10 5
4 ÷ 6 20 10
6 ÷ 8 35 20
8 ÷ 10 --- 35
10 ÷ 12 --- 50
Other stress related elements
(to be taken into consideration if the probability that
they occur is greater than 10% )
Surrounding temperature greater than 40°C
or lower than 0°C or humidity greater than 80%
10 10
Presence of dust and sand 15 15
Presence of salinity 20 20
Photo manoeuvre interruption 15 10
Stop manoeuvre interruption 25 20
Speed greater than “L4 fast” 20 15
Thrust active 25 20
Severity index total%:
Note: if the severity index exceeds 100%, this means that the conditions are beyond the acceptable limits; a larger model is therefore advised.
Severity index %
Durability in cycles

Table of Contents

Other manuals for Nice Robus 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice Robus 1000 and is the answer not in the manual?

Nice Robus 1000 Specifications

General IconGeneral
BrandNice
ModelRobus 1000
CategoryGate Opener
LanguageEnglish

Related product manuals