22
Domestic hot water
User
Superuser
Pause - Domestic hot water
It is possible to temporarily shut down hot water production. This may be a good idea when you go on holiday.
The production of hot water is paused in the Standby menu:
• CP/Pause SHW Hot water production shut down until the next change in the weekly schedule.
If you wish to pause hot water production while you are on holiday, any weekly schedule that you have created must
be deactivated.
Legionella combat system - Start Legionella combat system now.
The legionella combat system can be set to function automatically, but it is also possible to start it at any time that
suits you.
The legionella combat system is started in the Settings menu:
• CP/Legion mode/Start legionella now You can start the legionella combat system manually.
If you have been away on holiday for a long time and during this period have stopped the hot water production, it may
be beneficial to start the legionella function manually.
Legionella combat system - Settings
The legionella combat system can be set to function automatically.
The legionella combat system is set in the Settings menu:
• CP/Legion mode You can activate the combat system.
Off: Legionella combat system inactive.
Weekly: Legionella combat system runs once a week.
Monthly: Legionella combat system runs once a month
(factory setting: Off).
• CP/Legion mode/Day for anti-legionella Weekday or month in which the legionella combat system will run.
• CP/Legion mode/Legionella start (h) Time of day at which the legionella combat system will start.
The legionella combat system runs by heating the hot water to 65°C for 5 minutes. It is therefore a good idea to do this
a good time before showering, to avoid scalding.