8-81
8 Pulse Outputs
CJ2M CPU Unit Pulse I/O Module User’s Manual
8-9 Application Example
8
8-9-4 Feeding Wrapping Material: Interrupt
Feeding
z PLC Setup
Note The interrupt input setting is read from the PLC Setup when the power supply is turned ON.
z DM Area Settings
• Speed Control Settings to Feed Wrapping Material to Initial Position and Positioning Control Set-
tings for Wrapping Material
z Cyclic Task Program (Executed at Startup)
Preparations
Setting
Enable using input IN00 as interrupt input.
Setting Word Data
Acceleration rate: 500 pps/4 ms D10 #01F4
Deceleration rate: 500 pps/4 ms D11 #01F4
Target frequency: 10,000 pps D12 #2710
D13 #0000
Number of output pulses: 5,000
pulses
D14 #1388
D15 #0000
Ladder Program
2960.04 W0.01
W0.00
A280.03
2960.01
W0.00
W0.01
@IFEED
#0000
#0100
D10
@INI
#0000
#0003
0
Feeding Material with Speed Control
Start feeding
material
Material
being fed
Packaging
material
positioning
completed
Pulse output completed
Immediate stop
Immediate stop switch
Material being fed
Packaging material
positioning completed