Connection with Application Programs Section 7-2
149
7-2-3 Connection via Network
This section describes how to connect an application program on another
computer to the Ladder Engine via network (Ethernet).
Note When connecting via network, the routing table must be set for FinsGateway
and the relay network table for the Ladder Engine because two communica-
tions lines are required for the computer with the CX-Simulator
Note When connecting via Ethernet, the Runtime version of FinsGateway is sepa-
rately required for the computer with the CX-Simulator.
1,2,3…
1. Start the FinsGateway Service Manager to activate the CPU Unit and the
Ethernet Unit of FinsGateway.
2. Start the CX-Simulator to select the PLC data folder required to debug
application programs. Each window of [Work CX-Simulator], [CX-
Simulator Debug Console], and [System Status] will be displayed.
3. Clicking the [Target Comm. Unit] drop-down list in the [Work CX-
Simulator] window will display the list of usable communications units of
FinsGateway. Select Controller Link Unit in the list.
4. Click the [Connect] button to display the FINS address of the Ladder En-
gine in the [Guide to Connect].
Computer
FinsGateway
Ethernet
Ladder Engine