3 Communications Data for CompoWay/F
3 - 28
E5C-T Digital Temperature Controllers Programmable Type Communications Manual (H186)
DA (9A) 0015 Program 0 Time
Signal 2 OFF Time
H'00000000 to H'00009959 (0.00 to 99.59) (hours,
minutes)
H'00000000 to H'00009959 (0.00 to 99.59) (minutes,
seconds)
Program
setting
DA (9A) 0016 Program 0
Segment 0 Type
H'00000000 (0): Ramp
H'00000001 (1): Soak
H'00000002 (2): Step
DA (9A) 0017 Program 0
Segment 0 SP
SP lower limit to SP upper limit
DA (9A) 0018 Program 0
Segment 0 Slope
H'00000000 to H'0000270F (0 to 9999)
DA (9A) 0019 Program 0
Segment 0 Time
H'00000000 to H'00009959 (0.00 to 99.59) (hours,
minutes)
H'00000000 to H'00009959 (0.00 to 99.59) (minutes,
seconds)
DA (9A) 001A Program 0
Segment 1 Type
Same as for segment 0.
to to
DA (9A) 001E Program 0
Segment 2 Type
to to
DA (9A) 0022 Program 0
Segment 3 Type
to to
DA (9A) 0026 Program 0
Segment 4 Type
to to
DA (9A) 002A Program 0
Segment 5 Type
to to
DA (9A) 002E Program 0
Segment 6 Type
to to
DA (9A) 0032 Program 0
Segment 7 Type
to to
DA (9A) 0036 Program 0
Segment 8 Type
to to
DA (9A) 003A Program 0
Segment 9 Type
to to
DA (9A) 003E Program 0
Segment 10 Type
to to
DA (9A) 0042 Program 0
Segment 11 Type
to to
DA (9A) 0046 Program 0
Segment 12 Type
to to
DA (9A) 004A Program 0
Segment 13 Type
to to
Variable
type
Address Parameter name Setting (monitor) value Level