EasyManuals Logo
Home>Omron>Temperature Controller>E5AN

Omron E5AN Communications Manual

Omron E5AN
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #129 background imageLoading...
Page #129 background image
I-1
Index
A
addresses
CompoWay/F
................................................... 2-7
Modbus .............................................................. 5-7
area definitions ...................................................... 2-6
ASCII list .............................................................. A-2
B
BCC ....................................................... 1-3, 2-2, 2-3
C
command descriptions ......................................... 4-5
command frame
CompoWay/F
................................................... 2-2
Modbus .............................................................. 5-2
SYSWAY ......................................................... 4-2
command lists
SYSWAY
......................................................... 4-4
command text ................................................2-2, 2-6
communications baud rate ..........................1-7, 1-8
communications data
CompoWay/F
................................................... 2-4
CompoWay/F and SYSWAY ........................ 3-1
SYSWAY ......................................................... 4-3
communications data length .......................1-7, 1-8
communications methods .................................... 1-2
communications parameter setup ...................... 1-7
communications parameters .......................1-7, 1-8
communications parity ................................1-7, 1-9
communications protocol ............................1-7, 1-8
communications specifications .......................... 1-3
communications stop bits ............................1-7, 1-9
communications unit number .....................1-7, 1-8
communications writing selection ..................... 4-9
CompoWay/F ................................................1-2, 2-1
CRC-16 .................................................................. 5-3
D
data format
CompoWay/F
................................................... 2-2
Modbus .............................................................. 5-2
SYSWAY ......................................................... 4-2
E
Echoback Test
CompoWay/F
.........................................2-8, 2-18
Modbus ....................................................5-6, 5-20
end code
CompoWay/F
...........................................2-3, 2-4
SYSWAY .................................................4-3, 4-6
error code ............................................................... 5-5
ETX ......................................................................... 2-2
F
FCS ..........................................................................4-2
FINS ............................................................... 1-2, 2-3
function code .........................................................5-2
function list ............................................................5-6
I
interface ..................................................................1-4
M
Modbus ..................................................1-2, 5-1, 6-1
N
no response
Modbus
..............................................................5-5
node number .......................................................... 2-2
number of elements
CompoWay/F
................................................... 2-7
Modbus .............................................................. 5-8
O
Operation Command
CompoWay/F
........................................ 2-8, 2-19
P
PDU structure ........................................................ 2-6
protocol setting ...................................................... 1-8
R
Read Controller Attributes
CompoWay/F
........................................ 2-7, 2-16
Read Controller Status .............................. 2-8, 2-17
Read Initial Status ................................................. 4-4
Read Process Value ..................................... 4-4, 4-5
Read Set Values and MV Monitor
SYSWAY
.......................................................... 4-7
Read Variable Area
CompoWay/F
.......................................... 2-7, 2-9
response code list
CompoWay/F
................................................. 2-26
response frame
CompoWay/F
................................................... 2-3
Modbus .............................................................. 5-4
SYSWAY .......................................................... 4-3
RS-485 ....................................................................1-4
S
send data wait time ...................................... 1-7, 1-9

Table of Contents

Other manuals for Omron E5AN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron E5AN and is the answer not in the manual?

Omron E5AN Specifications

General IconGeneral
BrandOmron
ModelE5AN
CategoryTemperature Controller
LanguageEnglish

Related product manuals