8-2
8-1 Inverter Specifications
3-phase
Model 3G3JV- A2001 A2002 A2004 A2007 A2015 A2022
200-VAC
models
Power
supply
Rated voltage
and frequency
3-phase 200 to 230 VAC at 50/60 Hz
Allowable voltage
fluctuation
–15% to 10%
Allowable
frequency
fluctuation
±5%
Heat radiation (W) 13.0 18.0 28.1 45.1 72.8 86.5
Weight (kg) 0.5 0.5 0.8 0.9 1.3 1.5
Cooling method Natural cooling Cooling fan
Single-
Model 3G3JV- AB001 AB002 AB004 AB007 AB015 ---
phase
200-VAC
Power
supply
Rated voltage
and frequency
Single-phase 200 to 240 VAC at 50/60 Hz
models
Allowable voltage
fluctuation
–15% to 10%
Allowable
frequency
fluctuation
±5%
Heat radiation (W) 13.0 18.0 28.1 45.1 72.8 ---
Weight (kg) 0.5 0.5 0.9 1.5 1.5 ---
Cooling method Natural cooling Cooling fan
Max. applicable motor capacity (kW) 0.1 0.2 0.4 0.75 1.5 2.2
Output
specifi-
Rated output capacity
(kVA)
0.3 0.6 1.1 1.9 3.0 4.2
cations
Rated output current (A) 0.8 1.6 3.0 5.0 8.0 11.0
Rated output voltage (V) 3-phase 200 to 240 VAC (according to the input voltage)
Max. output frequency 400 Hz parameter setting
Control
charac-
Harmonic-current
countermeasures
DC reactor (option) connection possible
teristics
Control method Sine wave PWM (V/f control)
Carrier frequency 2.5 to 10.0 kHz (in vector control)
Frequency control range 0.1 to 400 Hz
Frequency precision
(temperature
characteristics)
Digital commands: ±0.01% (–10°C to 50°C)
Analog commands: ±0.5% (25°C ± 10°C)
Frequency setting
resolution
Digital commands: 0.1 Hz (less than 100 Hz) and 1 Hz
(100 Hz or over)
Analog commands: 0.06 Hz/60 Hz (equivalent to 1/1000)
Output frequency
resolution
0.01 Hz
Specifications Chapter
8