Using the FTP Server Function Section 11-3
11-3-3 FTP Tab
The CPU Bus Unit System Setup, which is set when using the FTP server
function, is shown in the CX-Programmer's Edit Parameters Dialog Box.
â–  Settings
Setting Details Default value
Login Set the login name to externally connect to
the EtherNet/IP Unit or built-in EtherNet/IP
port via FTP.
None
(CONFIDENTIAL is
used.)
Password Set the password to externally connect to the
EtherNet/IP Unit or built-in EtherNet/IP port
via FTP.
None
Port No. FTP port number of the EtherNet/IP Unit or
built-in EtherNet/IP port.
This setting does not normally need to be
changed.
FTP uses two ports: a port for control and a
port for data transfer. Set the control port
only. The data transfer port uses the value
set for the control port –1.
0
(21 is used.)