141
Setting Tag Data Links Section 6-2
6-2-5 Connection Settings
After creating the tag sets, click the Connections Tab at the top of the Edit
Device Parameters Dialog Box, and set the following connection information.
• The target devices with which connections will be opened
• Whether the tag sets are input or output tag sets
• The length of the packet intervals (RPI)
Make the Connections settings in the originator only. The Connections set-
tings are not necessary in the target device.
Note Make the Connections settings after creating tag sets for all of the devices
involved in tag data links.
Connection Settings (Connections Tab)
Registering Devices in the Register Device List
1,2,3... 1. Display the originator device’s Edit Device Parameters Dialog Box by dou-
ble-clicking the device’s icon in the Network Configuration Window, or
right-clicking the device’s icon and selecting Parameter - Edit from the
pop-up menu.
2. Click the Connections Tab at the top of the Edit Device Parameters Dialog
Box. All of the devices registered in the network (except the local node) will
be displayed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CJ1W-EIP21 and is the answer not in the manual?

Omron SYSMAC CJ1W-EIP21 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CJ1W-EIP21
CategoryNetwork Hardware
LanguageEnglish

Related product manuals