Setting the Operating Environment of the System
299
7
Changing the System Environment
Vision System FH/FZ5 Series
User’s Manual (Z340)
3 Enter the information to be allocated to
the network drive (shared name), such
as the shared folder, user name, and
password.
4 Click the [Apply] button.
The settings are enabled after the Controller is restarted.
Parameter
Set value
[Factory default]
Description
Share name S,T,U,V,W,X,Y,Z
This is the name to be recognized by the Controller as a network
drive. Only 1 unit can be connected.
For FZ5-L3 or FZ5-6, the shared name is displayed in the
\Network folder.
For the FH or FZ5-11, a drive letter such as E:, F:, G:, or H: is
displayed.
Shared folder ---
Specify the shared folder name.
Create a folder in advance on a computer that has a DNS resolved
name on the network, and specify this as the shared folder name. For
example, if the host name (computer name) is VISION and the shared
name is COMMON, specify a name such as \\VISION\COMMON.
Username --- Enter the user name and the password to access the network drive.
If you do not know the user name or the password, contact the device
network administrator.
Password ---
With the FH/FZ5-11, you can still connect to the network drive even if you specify the IP address instead of the host
name when you set the shared folder name. With the FZ5-L35/FZ5-6, you will not be able to connect to the network
drive if you specify the IP address.
• If images and data are logged to a network drive, the use of the multi-input function and other heavy measurement loads
on the Controller may slow down communications and cause logging errors. In this case, set the measurement takt time
so that there is some leeway.
• If many drives are set as network drives, it may require a greater amount of time to start the Controller.
• Do not pull out the LAN cable while the Controller is accessing the network drives.
• Start the Controller when the network drives are ready. Connections cannot be established if the network drives are not
ready when the Controller is started.
• If there is no access to a network drive for a certain amount of time, the connection will be automatically cut off
depending on the network drive setting at the connection target. Make sure that the setting at the connection target is not
set to automatic disconnection.
• Dates and Times of the Updates of the Files Created at Network Logging
If the time zone of the external device is different from the time zone setting of the Controller [GMT-08:00 Pacific Time
(US & Canada): Do not automatically adjust clock for Daylight Saving Time], the date and time actually written may be
different from the date and time of the file update. Adjust the time zone of the external device to match that of the
Controller.
Note
IMPORTANT

Table of Contents

Other manuals for Omron SYSMAC FH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC FH Series and is the answer not in the manual?

Omron SYSMAC FH Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC FH Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals