Setting the Operating Environment of the System
300
Vision System FH/FZ5 Series
User’s Manual (Z340)
Checking System Information: [System Information]
The Controller model and measurement application version can be checked.
You can check the external memory status only on the FH and the FZ5-11.
Reference: Using External Memory Devices (FH and FZ5-11 Only) (p.256)
1 In the Main Window, select [System
information] from the [Function] menu.
The [System information] dialog box is
displayed.
2 Check the information.
The Controller model and measurement
application version can be checked.
3 Click the [Memory state] button.
You can check the following information.
Available Application Memory
The application memory is the memory that is used by all applications.
Knowing the available memory provides a rough standard for confirming status while operating.
Available data memory (FZ5-L3 or FZ5-6 only)
The data memory is the amount of memory that can be used for scene group data. Check the available
memory that can be used for unit data and settings data for each unit.
4 Click the [Close] button.
The [System information] dialog box closes.
Application Memory
This memory is used for all applications.
This memory area is used temporarily by the application. By confirming available memory, this provides a rough
standard for confirming status while operating. The user cannot access it.
With the FH or FZ5-11, a warning message is displayed when the amount of available application memory falls
below 1 GB. Adjust the inspection flow so that the available memory is more than 1 GB.
Data Memory (FZ5-L3 or FZ5-6)
This memory is used to hold the current setting details of scene group data.
If the capacity of this memory is exceeded, adding units and copying scenes cannot be performed to edit the flow.
The available data memory can be checked from the system menu.
Reference: Checking System Information: [System Information] (p.300)
Note

Table of Contents

Other manuals for Omron SYSMAC FH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC FH Series and is the answer not in the manual?

Omron SYSMAC FH Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC FH Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals