WWW.NNC.IR
Macro Reference
456
Vision System FH/FZ5 Series
User’s Manual (Z340)
Debug
Set the program execution form and information output method.
Format
Debug <mode>
Parameter
Return value
None.
Description
Sets the program execution form and information output method specified in the <mode> parameter.
Debug mode can be set to debug the program using macro functions that are only executed in debug mode.
Set the mode to release mode after the debug so that there will be no need of removing DebugPring
functions and other macro functions that are only used in debug mode from the program. (How to Use the
Debug Function (p.235))
If an incorrect data type is specified for a parameter, a "Type mismatch" error will occur.
If a non-existent number, numerical value, or combination of data types or values are specified for a
parameter, an "Illegal function call" error will occur.
If the format is written incorrectly, such as writing the macro function name incorrectly, omitting a comma, or
omitting a half-width space, a "Syntax error" error will occur.
Usage Cautions
• None.
Parameter
name
Data type Description
<mode> Integer type
Execution form and information output method
0: Release mode, no error description is output when an error occurs
1:
Release mode, an error description is output to the system status console
window when an error occurs.
2:
Release mode, the contents of each line are output to the system status
console window when the program is executed.
3:
Release mode, an error description is output to the message box when an
error occurs.
16: Debug mode, no error description is output when an error occurs
17:
Debug mode, an error description is output to the system status console
window when an error occurs.
18:
Debug mode, the contents of each line are output to the system status console
window when the program is executed.
19:
Debug mode, an error description is output to the error box when an error
occurs.

Table of Contents

Other manuals for Omron SYSMAC FH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC FH Series and is the answer not in the manual?

Omron SYSMAC FH Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC FH Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals